A rainscreen (dry-joint) ticket and a wet-seal ticket are not the same shop package. The joint changes the extrusions, returns, part marks and how the panels are called out on the drawings. CNC Metalcraft® fabricates both for ACM/MCM and for plate. We will not substitute one joint for the other because a set is silent.
Updated November 2026 · CNC Metalcraft
A dry-joint rainscreen and a wet-seal (barrier) panel can look similar on a small elevation, and they are not the same ticket in the shop. The joint type changes the extrusion package, the return, the way parts are marked, and sometimes the way they are packed. CNC Metalcraft® fabricates both, in ACM and in plate, in over 75,000 sq ft across two Burnsville, MN buildings. We do not choose the joint for the design team. We need the joint named on the drawings so we build the right one.
Sure-Panel® is the systems brand. Read ACM dry-joint rainscreen and ACM wet-seal panels (and the matching plate pages) for performance language, joint drawings and specifications. This article is the fabricator’s list of what has to be on the set before we can draft or fabricate honestly.
What does a rainscreen ticket actually ask the shop to make?
It asks for rout-and-return ACM/MCM or plate panels that hang on a rainscreen extrusion, with a dry joint and no caulk line as the primary seal at the panel edge. The Sure-Panel® ACM rainscreen system is the published dry-joint system we fabricate. Extrusions, marks and packing have to match that system, not a wet-seal set.
A dry-joint rainscreen is, on our floor, a rout-and-return panel hung on a Sure-Panel® aluminum extrusion system, with no caulking in the joint as a design intent. The extrusion package travels with the panels. The returns, the clip or extrusion layout, and the marks all have to match the approved detail. If the drawings say “rainscreen” and show a wet-seal profile, or the other way around, we will stop and ask. It is not a field decision.
The live CNC composite page describes rainscreen panels as rout-and-return panels installed with the proprietary Sure-Panel® aluminum extrusion system, with no caulking or exposed fasteners as the intended appearance. That is the shop target when the drawings call for that system. It is not a license to substitute a wet seal because the sheet is already on the table.
What does a wet-seal ticket ask the shop to make?
It asks for panels whose joints are detailed for backer rod and sealant in the field. Clips, returns and marks follow the wet-seal details, not the dry-joint extrusion package. ACM/MCM and plate can both be built this way when the drawings say so. A wet-seal mark in a rainscreen opening is a drawing or packing error.
A wet-seal or caulk-joint panel is still a fabricated panel, often still rout-and-return, but the joint is designed to take sealant. The edge condition, the return and the mark are different from a dry joint, and the installer is not hanging the same part. Periodic resealing, when a designer or a maintenance plan calls for it, is an ownership and design topic, not a fabrication step. We will not add a maintenance claim here that is not on our live shop pages.
Wet-seal work shows up on real buildings we have fabricated, including wet-seal ACM on a high school in Blaine, Minnesota, and a caulk-joint ACM job at a city hall in Oak Grove, Minnesota. Those are Minnesota examples, described by building type and city. They do not require a Dallas–Fort Worth or Atlanta project to be wet seal, or rainscreen. The drawings decide.
What has to be on the shop drawings either way?
The system name, the joint type, the material (ACM/MCM or plate, with thickness and, for ACM/MCM, the core), the finish, the elevations and the delivery address. If we draft, production is about six to eight weeks from shop-drawing approval. If you issue approved fabrication drawings, fabrication takes three to four weeks.
The system name, the joint type, the material (ACM or plate, with thickness and, for ACM, the core), the finish, the elevations, and the delivery address. If we draft, we issue shop drawings for approval, and every part later carries a mark that matches those drawings. Production then takes about six to eight weeks starting on the approval date. If you issue approved fabrication drawings, fabrication takes three to four weeks. Freight from Burnsville is a separate planning number.
A mixed wall — rainscreen on the field, wet seal at a particular condition, plate at grade — should be called out as mixed, with each part family marked so a crate can be opened in the right order. Tight sites in Chicago or downtown Nashville benefit from packing by elevation or phase; that request should be on the order, not on a phone call the day the truck is loaded.
| On the drawings | Rainscreen (dry joint) | Wet seal |
|---|---|---|
| Joint intent | Unsealed / dry joint, as detailed | Joint designed to take sealant, as detailed |
| Shop needs | Extrusion package, returns, marks that match the dry-joint detail | Edge and return conditions, marks that match the wet-seal detail |
| Material | ACM or plate, as specified | ACM or plate, as specified |
| Who chooses | The design team. We fabricate the system that is approved. | |
How do lead time and freight sit on top of the joint choice?
They do not change because the joint is dry or wet. They change because of drawings and distance. The clocks are three to four weeks with approved fabrication drawings, or about six to eight weeks of production from shop-drawing approval when we draft. Freight from Burnsville is added after the crates are ready.
They do not change because the joint is dry or wet. They change because of drawings and distance. The two fabrication clocks are the same clocks we use on every architectural metal order, and they are spelled out in our article on lead times and shop drawings. A three-day planning run to Houston or Atlanta, or a one-day run to Chicago, is added after the crates are ready. Receiving still means counting crates against the packing list, photographing exceptions before the driver leaves, and getting finished faces out of weather they were not meant to sit in.
Concealed-fastener options, including Sure-Panel® Quick-Snap™, are a different attachment family again. If the set calls for Quick-Snap™, name it. Do not assume a rainscreen extrusion package and a Quick-Snap™ package are interchangeable on the floor. For product downloads and 3-part specifications, stay on sure-panel.com. For the shop, stay here: composite, plate, and the quote form.
What is this article not trying to decide?
It is not a performance comparison, a water-test comparison or a recommendation of one joint over the other. Those topics belong on Sure-Panel®, and only with claims already published there. This page is the shop-side companion: what has to be on the ticket so ACM/MCM or plate is built as the joint the drawings require.
It is not a performance comparison, a water-test comparison, or a recommendation. Those topics belong on Sure-Panel®, and only with the claims already published there. It is also not a Midwest-only article. The shop process is the same whether the crates are going a day to Chicago or three days to Atlanta. What changes by city is freight, receiving and, on our metro pages, the DOE energy-code listing and the climate-zone notes. None of those city facts pick the joint for you.
Installers who open a crate and find a mark they cannot place on the elevation should call the shop, weekdays, 7 a.m. to 4 p.m. Central Time, before they force a part into the wrong opening. A dry-joint mark in a wet-seal opening is a drawing problem or a packing problem, not a jobsite improvisation. The packing list, the shop drawings and the crate marks are meant to be read together, which is why we spend time on labeling in the first place.
If you are writing a specification, name the joint in the section that names the material, and keep the Sure-Panel® system name consistent with the details you attach. If you are bidding, bid the joint that is drawn, and ask a written question if the elevation and the specification disagree. That question is cheaper than a second shop-drawing cycle.
What questions come up most often?
Teams ask whether one job can mix rainscreen and wet-seal panels (yes, when each family is drawn and marked), whether the joint changes the fabrication clock (it does not), and where the system details and CAD files live. The short answers below point to those published sources.
Can a job mix rainscreen and wet-seal panels?
Yes, if the drawings say so and each part family is detailed and marked. We will not substitute one joint for the other in the shop.
Does the joint type change the three-to-four or six-to-eight-week clock?
No. The clocks depend on who issues the drawings, not on whether the joint is dry or wet. Freight is added after the crates are ready.
Where are the system details and CAD files?
On sure-panel.com, on the rainscreen, wet-seal, plate and Quick-Snap™ pages and in the specifications library. CNC Metalcraft® is the fabricator of those systems.
How do I request a quote?
Send the drawing set through the quote form, or call the shop weekdays, 7 a.m. to 4 p.m. Central Time. Name the joint, the material (ACM/MCM or plate) and the delivery city. If a building mixes joints, say which elevations are which. The Burnsville address and shop numbers are in the next paragraph.
Send a drawing set through request a quote, or call (952) 938-3356 or 888.938.3356, weekdays 7 a.m. to 4 p.m. Central Time. CNC Metalcraft®, 11901 Riverwood Dr, Burnsville, MN 55337. Founded in 2005. The plant is over 75,000 sq ft across two Burnsville, MN buildings.